To Download Datasheets Select Below and Click Download
-
VT-901N Polyimide No Flow / Low Flow Prepreg
Version: 29/09/2023 /40/41/42General Information
Polyimide Low and No Flow product using Ventec’s VT-901N resin technology with an epoxy component for flow control and enhanced bond strength designed for use in polyimide rigid-flex applications.
- Improved for high layer count rigid-flex
- Tg 200℃
- Low Z-CTE
- Meets IPC-4101E Specification sheets /42
- Compatible with Lead Free processing
Storage Condition
Prepreg Storage Condition Temperature < 23℃ (73℉) < 5℃ (41℉) Relative Humidity < 55% / Availability
Product Type Glass Fabric Resin Content Flow Range * Pressed Thickness mil mm mil/ply mm/ply VT-901N Polyimide Tg 200˚C 106 NF 106 64% 10~50 0.25~1.25 1.8 0.046 1080 NF 1080 60% 10~50 0.25~1.25 2.8 0.071 106 LF 106 65% 60~120 1.5~3 1.9 0.048 106 LF 106 68% 60~120 1.5~3 2.1 0.053 1080 LF 1080 62% 60~120 1.5~3 3.1 0.079 Note: * Built on IPC-TM650 2.3.17.2
Properties Sheet of Pressed No Flow Prepreg
Test Item Test Method (IPC-TM-650) Unit Typical Value Tg TMA 2.4.24 ℃ 200 Td TGA ASTM D3850 ℃ 390 Electric Strength 2.5.6.2 KV/mm 54 Peel Strength with 1oz Cu As Received 2.4.8 Lb/in 8-9 After Thermal stress 8-9 Peel Strength with CVL 2.4.8 Lb/in 7 Moisture Absorption D24/23 2.6.21 % 0.20 After PCT 1atm., 121℃, 1hour % 0.22 X,Y-axis CTE 30~125℃ 2.4.24 ppm/℃ 12~15 Z-axis CTE Before Tg 2.4.24 ppm/℃ 50 After Tg ppm/℃ 230 50~260℃ % 2.5 Thermal Stress Solder dip at 288℃ 2.4.13.1 Second >300 Breakdown Voltage D48/50+D0.5/23 2.5.6 KV >60 Arc Resistance D48/50+D0.5/23 2.5.1 Second 150 Dk (RC60% at 1GHz) C24/23/50 2.5.5.9 - 3.8 Df (RC60% at 1GHz) C24/23/50 2.5.5.9 - 0.015 All test data provided are typical values and not intended to be specification values.
Press Condition
VT-901N Heating rate of materials 2.5~3.5ºC/min (4.5~6.5ºF/min) Cure Temperature ≥190ºC Cure Time >90min Vacuum should be continued until over 140ºC (284ºF) [Material Temperature] Pressure on materials: Start with 100psi, Full pressure: 250~450psi Cold Press: Keep Plate @ Room Temperature by water; Pressure:100psi; Dwell Time: 60minutes Contact Ventec technical service to discuss the specific condition.